MODEL
CAEK
1:1 pilot ratio, vented counterbalance valve - atmospherically referenced
SERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The check
valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief
valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate
determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamber
is atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATA
Pilot Ratio 1:1
Maximum Recommended Load Pressure at Maximum Setting 215 bar
Maximum Setting 280 bar
Factory Pressure Settings Established at 30 cc/min.
Maximum Valve Leakage at Reseat 0,3 cc/min.
Check Cracking Pressure 1,7 bar
Adjustment - Number of Counterclockwise Turns to Increase Setting 5
Reseat >85% of setting
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-302-007
Seal kit - Cartridge Viton: 990-302-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGE
H 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard Setting
I 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
snhy.com/CAEK
TECHNICAL FEATURES
Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
Turn adjustment clockwise to decrease setting and release load.
Full clockwise setting is 200 psi (14 bar).
Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
Model Code Example: CAEKLHNCONFIGURATION OPTIONS
Created on 12/08/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
This valve has positive seals between all ports.
With vented valves, a lower pilot ratio may be required to achieve machine stability compared to non-vented valves.
Three-port vented valves are atmospherically referenced and considered problem solvers for existing circuits using non-vented valves. Over time, the vented valves
may leak externally or allow moisture into the spring chamber. Four-port vented counterbalance valves are recommended for new applications.
All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.